Certificate of Analysis
Every batch is tested by SideChain Analytics, an independent laboratory in Mississauga, Ontario. Identity, mass, purity and net peptide content are measured by LC-MS/MS, and each certificate is published here as its batch clears testing.
Uncategorized
Uncategorized
Uncategorized
Uncategorized
Uncategorized
Uncategorized
Batch 1, every certificate
Every certificate for the batch on sale: three vials of each compound and two of the KLOW Blend, received by the laboratory on August 20, 2026 and reported on August 27 and 28. Net peptide content is what the lab measured against the label claim. Purity is chromatographic purity by LC-MS/MS. The purity shown on a card above is the lowest figure among that product's vials.
Every row links to the laboratory's own verification page for that report, and to the page of the certificate inside the product's PDF.
| Product | Lab sample | Certificate | Label claim | Net peptide content | Purity | Identity | Reported | |
|---|---|---|---|---|---|---|---|---|
| Tirzepatide 20 mg | TIR-038_D | COA-2026-SC-01503 | 20.00 mg | 22.07 mg (110%) | 99.7% | Confirmed | Aug 27, 2026 | Verify at lab · PDF |
| Tirzepatide 20 mg | TIR-039_D | COA-2026-SC-01502 | 20.00 mg | 22.16 mg (111%) | 99.6% | Confirmed | Aug 27, 2026 | Verify at lab · PDF |
| Tirzepatide 20 mg | TIR-040_D | COA-2026-SC-01501 | 20.00 mg | 21.88 mg (109%) | 99.7% | Confirmed | Aug 27, 2026 | Verify at lab · PDF |
| Semaglutide 10 mg | SEM-004_D | COA-2026-SC-01512 | 10.00 mg | 10.70 mg (107%) | 99.7% | Confirmed | Aug 27, 2026 | Verify at lab · PDF |
| Semaglutide 10 mg | SEM-005_D | COA-2026-SC-01511 | 10.00 mg | 10.40 mg (104%) | 99.7% | Confirmed | Aug 27, 2026 | Verify at lab · PDF |
| Semaglutide 10 mg | SEM-006_D | COA-2026-SC-01510 | 10.00 mg | 11.06 mg (111%) | 99.7% | Confirmed | Aug 27, 2026 | Verify at lab · PDF |
| Retatrutide 10 mg | RET-371_D | COA-2026-SC-01509 | 10.00 mg | 10.90 mg (109%) | 99.4% | Confirmed | Aug 27, 2026 | Verify at lab · PDF |
| Retatrutide 10 mg | RET-372_D | COA-2026-SC-01508 | 10.00 mg | 10.57 mg (106%) | 99.6% | Confirmed | Aug 27, 2026 | Verify at lab · PDF |
| Retatrutide 10 mg | RET-373_D | COA-2026-SC-01507 | 10.00 mg | 10.60 mg (106%) | 99.4% | Confirmed | Aug 27, 2026 | Verify at lab · PDF |
| GHK-Cu 100 mg | GHK-068_D | COA-2026-SC-01515 | 100.00 mg | 118.06 mg (118%) | 99.7% | Confirmed | Aug 27, 2026 | Verify at lab · PDF |
| GHK-Cu 100 mg | GHK-069_D | COA-2026-SC-01514 | 100.00 mg | 102.67 mg (103%) | 99.6% | Confirmed | Aug 27, 2026 | Verify at lab · PDF |
| GHK-Cu 100 mg | GHK-070_D | COA-2026-SC-01513 | 100.00 mg | 92.39 mg (92%) | 99.7% | Confirmed | Aug 27, 2026 | Verify at lab · PDF |
| PT-141 10 mg | PT-015_D | COA-2026-SC-01521 | 10.00 mg | 11.33 mg (113%) | 99.6% | Confirmed | Aug 27, 2026 | Verify at lab · PDF |
| PT-141 10 mg | PT-016_D | COA-2026-SC-01520 | 10.00 mg | 11.82 mg (118%) | 99.7% | Confirmed | Aug 27, 2026 | Verify at lab · PDF |
| PT-141 10 mg | PT-017_D | COA-2026-SC-01519 | 10.00 mg | 10.14 mg (101%) | 99.6% | Confirmed | Aug 27, 2026 | Verify at lab · PDF |
| KLOW Blend 80 mg | BLD-168_D | COA-2026-SC-01506 | TB-500: 10.00 mg | 10.89 mg (109%) | 99.6% | Confirmed | Aug 28, 2026 | Verify at lab · PDF |
| KLOW Blend 80 mg | BLD-168_D | COA-2026-SC-01506 | BPC-157: 10.00 mg | 10.63 mg (106%) | 99.8% | Confirmed | Aug 28, 2026 | Verify at lab · PDF |
| KLOW Blend 80 mg | BLD-168_D | COA-2026-SC-01506 | GHK-Cu: 50.00 mg | 55.00 mg (110%) | 99.5% | Confirmed | Aug 28, 2026 | Verify at lab · PDF |
| KLOW Blend 80 mg | BLD-168_D | COA-2026-SC-01506 | KPV: 10.00 mg | 10.13 mg (101%) | 99.7% | Confirmed | Aug 28, 2026 | Verify at lab · PDF |
| KLOW Blend 80 mg | BLD-169_D | COA-2026-SC-01505 | TB-500: 10.00 mg | 10.28 mg (103%) | Not determined | Confirmed | Aug 28, 2026 | Verify at lab · PDF |
| KLOW Blend 80 mg | BLD-169_D | COA-2026-SC-01505 | BPC-157: 10.00 mg | 10.49 mg (105%) | Not determined | Confirmed | Aug 28, 2026 | Verify at lab · PDF |
| KLOW Blend 80 mg | BLD-169_D | COA-2026-SC-01505 | GHK-Cu: 50.00 mg | 54.37 mg (109%) | 99.9% | Confirmed | Aug 28, 2026 | Verify at lab · PDF |
| KLOW Blend 80 mg | BLD-169_D | COA-2026-SC-01505 | KPV: 10.00 mg | 9.92 mg (99%) | 99.7% | Confirmed | Aug 28, 2026 | Verify at lab · PDF |
"Not determined" is the laboratory's own wording where a component's purity was not read on that vial. Identity and net content were confirmed on every component of every vial.
Why the certificate, not the claim
A certificate of analysis is the only thing standing between a claim and a fact. Purity printed on a website is marketing. Purity printed on a dated report from an independent laboratory, tied to a sample you can trace to the batch in your hand, is evidence.
Every MapleBloom batch is tested by SideChain Analytics, an independent third-party laboratory in Mississauga, Ontario, with no ownership connection to us. We publish each certificate here before the batch goes on sale. If a batch has not been tested, it is not on the site.
What we test for
- Identity, by LC-MS/MS. The laboratory confirms the molecule is the compound named on the label from its mass and its fragmentation pattern, using the same precursor-to-product transitions it would use for a reference standard. A vial can be clean and still be the wrong thing, which is why identity is its own line on every certificate.
- Chromatographic purity. The sample is separated by liquid chromatography and the target peptide's peak is read as a share of the total peak area (Ph. Eur. 2.2.46). It bounds peptide-related impurities, not excipients, counter-ions or residual water. The report includes the chromatogram, not just a number.
- Net peptide content. How many milligrams of the named peptide the vial actually holds, quantified against an external calibration and reported next to the label claim. The rest of the vial's mass is bulking agent, which is why a vial can look like more or less material than its milligram figure suggests.
We do not commission sterility, endotoxin or heavy-metal testing, and we do not claim it.
How to verify a certificate yourself
Do not take our word for any of this. Check it.
- Verify it with the laboratory. Every certificate carries a report number and a verification code. Enter the code at sidechainanalytics.com/verify, or use the link in the table above, and the laboratory confirms it issued that report for that sample. A certificate the lab does not recognise is not a certificate.
- Check the compound. The compound named on the certificate should be the compound on your vial, and the certificate should belong to the batch on sale. Only one batch of each compound is on sale today, so the certificates on this page cover every vial we ship.
- Check the laboratory is real. Search SideChain Analytics. It should be a findable, independent company with a real address and instrumentation it will name, and it should not be us. A lab whose logo appears only on a vendor's own website is not a lab.
- Read the date. Certificates should be recent and there should be several of them. One undated report covering an entire catalogue for a year means testing happened once, if at all.
- Look at the chromatogram. A purity figure with no chart behind it is a number someone typed.
- Watch the wording. "Typical purity" and "up to 99%" describe hopes. A certificate describes one sample on one date.
Certificates are the specification
The certificate published for a batch is the specification for that batch. It describes the material it names and does not carry over to any other batch, which is why we publish a new one every time.
Certificates stay published after a batch sells out. A supplier who tests every batch accumulates a public record over time, and that record is the point.
Questions about a certificate
Email info@getmaplebloom.com with the report number. We will send the full report and answer questions about what is on it. We cannot answer questions about handling material for any use other than laboratory research.
All products are for laboratory and research use only. Not for human or veterinary use. They are not drugs, supplements, foods, or cosmetics and have not been evaluated by Health Canada. 19+.